Cross section in cm | 40-20 | 50-25 | 50-30 | 60-30 | 60-35 | 70-40 | 80-50 | 100-50 | |
| | | | | | | | n/a | Duct fans ranging from 1,000 to 11,000m3/h with 230v and 400v options |
| | | | | | | | n/a | EC Duct fans can be delivered with a pre-wired potentiometer (0-10V) which allows you to easily find the desired working point. EC fans are notable for their economical use of energy and excellent ease of control |
| | n/a | | | | | | n/a | EC Duct fans insulated. RSI models are thermally and acoustically insulated with 50 mm of mineral wool, with perforated sheet steel on the inner surface. To protect the motor from overheating the RSI fans have integral thermal contacts with external leads for connection to a motor protection device. The fans can be installed in any position and are easy to connect using the DS flexible connections. The casing is manufactured from galvanised sheet steel. |
| n/a | | | | | | n/a | n/a | ATEX duct fans. Explosion proof versions comply with EN 50014, EN 50019, EN 1127-1 and EN 13463-1. Improved safety in accordance with EEx e II T3. ?x II 2G Certified according to ATEX |
| | | | | | | | n/a | Counter Flange - Used as a flange for mounting to the duct system. Manufactured from galvanised sheet steel. |
| | | | | | | | | LDR Silencer. Easily-fitted silencer immediately before or after the KE, KT, RS and RSI rectangular duct fans. Effectively suppresses noise transmitted to the duct. The silencer should be used together with an insulated fan where there is a requirement for noise suppression both in the duct and in the surroundings as a whole. . |
| | | | | | | | | LDR-B Silencer. Rectangular baffle silencer is fitted with built-in baffles and side baffles located outside the fitting dimension and has an external shell of trapezoidal corrugated sheet for stability and reduced risk of natural oscillation. LDR-B is designed for low air resistance with baffle combinations that dampen particularly low-frequency noise well. |
| | n/a | | | | n/a | | | Single or double diffusion grilles direct the air using adjustable blades in a horizontal, as well as vertical direction. Designed for air supply / air extract - for a balanced distribution of air through the entire diffusion grille it is recommended to use a damper or a plenum box. |
| | n/a | | | | | | n/a | Germicidal chamber without a fan for rectangular ducts equipped with UVc ultraviolet lamps for new builds or easily retrofitted into existing ducts. |
| | n/a | | | | | | n/a | As above in terms of UVc but with the addition of F7 & F9 filters. NB When retrofitting, the system may need to be ammended to overcome pressure drop due to the filtration section. |
| | n/a | | | | | | n/a | As above but with a tighter filtration specification. |
| | | | | | | | | Cold water-cooling battery for rectangular ducts with galvanised steel casing, copper tubes and aluminium fins. Drip pan from stainless steel. MWP 1.0 MPa (10 bar). Two inspection covers for cleaning and maintenance. Droplet separator as an accessory. Air velocities from 2,5m/s. |
| | | | | | | | | As above but incorporating a DX coil. DXRE are mostly used for central cooling of the ventilation air but can also be used for individual cooling of the air supplied to individual rooms (zones). |
| | | | | | | | | Electric Heater battery for rectangular ducts. Aluzinc-coated sheet steel with a heating element in stainless steel. The heater has integral overheating protection with a manual reset function. Suitable for control by room thermostat or TTC. 400v ranging from 9 to 80kW |
| | | | | | | | | LPHW heater battery for heating air in rectangular ducts. Hot-zinc-coated casing, heat transmission element with copper tubes and aluminium fins. The water-heating battery can be installed in a horizontal or vertical duct with an optional direction. 16bar WP at 100C water temp |
| | | n/a | | n/a | | | | Compact Supply AHU for residential and small commercial applications. |
| | n/a | | n/a | n/a | n/a | n/a | n/a | Compact Heat Recovery AHU. Topvex FC is a series of efficient ventilation units designed for suspended ceiling installations. The units are especially designed to meet stringent energy requirements with low energy use and high-efficiency heat recovering. |
| n/a | n/a | | | | n/a | n/a | | Volume control damper with the same flange system as rectangular duct fans. Air tightness class 3. The shutter valve consists of a number of blades which close towards each other, mounted inside a steel sleeve on bushes of glass-fibre reinforced nylon. The linkage is protected so that the valve can be insulated together with the duct. Blades and sleeve coupling are from galvanised sheet steel. |
| | | | | | | | | Fire dampers represent passive fire protection, designed with the help of compartmentalization to prevent the spread of toxic gases, smoke and fire. All our standard fire dampers are designed and certified in accordance with the test criteria EIS according to EN 1366 – 2. |
| | | | | | | | | Rectangular Smoke Control Damper for one (single) fire compartment with Automatic Activation, CE certified in accordance with the EN 12101-8, tested according to EN 1366-10 and classified in accordance with EN13501-4. |
| | | | | | | | | Single or double skin circular VAV (Variable Airflow Volume) controllers are commonly used for return air applications or for supply air applications. Ideal for single zone control with supply and return in Master and Slave setup such as offices, hotel rooms or meeting rooms or larger public or industrial halls where the required cooling and heating load will vary on demand. |
| | | | | | | | | Control and shut off damper for rectangular ducts with blade tightness class C4, tested to EN 1751. Ideal where different parts of the system need to be airtight separated from each other. It can be used on air handling units as outer shut-off damper or with modulating actuator as control damper. Supplied in a manual or motorized version with position indicator. |
| n/a | | | | | n/a | n/a | n/a | Flexible connections for in-duct fans. The connections fit exactly to the fan and are easily bolted to fan and duct. |
| | | | | | | | | Rectangular Filter Cassettes can be designed for a range of filtration products including bag filters. Filter cassettes can be connected directly on to the duct and should generally be fitted in a flat or vertical position. If fitted vertically, the direction of the air flow must be downwards so that the filter bags do not collapse. The cassette are often fitted with connections for a pressure sensor to be added. |